MODEL CO2120PN—User’ s Manual 120V Plug-In Carbon Monoxide Alarm W ith Silence Feature M06-1044-000 6/99 120V AC 60 Hz .085A Standby .087A Alarm.
T ABLE OF CONTENTS CHAPTER 1: INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Basic Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1 CHAPTER 1: Introduction BASIC SAFETY INFORMATION IMPORT ANT! Dangers, W arnings, and Cautions alert you to important operating instructions or to potentially hazar dous situations. Pay special attention to these items. IMPORT ANT! THIS IS NOT A SMOKE ALARM! This CO Alarm is designed to detect carbon monoxide fr om ANY source of combustion.
2 HOW Y OUR CO ALARM WORKS General Information CAUTION! Leave your CO Alarm plugged in year -round. CO problems can occur any time during the year , and this alarm can only alert you if it is plugged in and r eceiving power . This CO Alarm is intended for use in a standar d, unswitched 120V AC wall outlet.
3 WHAT THE LIGHTS AND ALARM T ONES MEAN During Power Up (or After Power Outage) Green light ON. Y ellow & red lights OFF . Horn “chirps” once. During an Alarm Green light ON. Y ellow light OFF . Red light FLASHES. Repeating horn pattern: 4 beeps, then a pause, 4 beeps, then a pause.
4 CO ALARM SPECIFICATIONS Gas Detection at T ypical T emperature and Humidity Ranges: The CO Alarm is not formulated to detect CO levels below 30 ppm typically . UL tested for false alarm resistance to Methane (500 ppm), Butane (300 ppm), Heptane (500 ppm), Ethyl Acetate (200 ppm), Isopropyl Alcohol (200 ppm) and Carbon Dioxide (5000 ppm).
5 CHAPTER 2: Installation WHERE TO INSTALL CO ALARMS The Consumer Pr oduct Safety Commission (CPSC) recommends the use of at least one CO Alarm per household, located near the sleeping area. For added pr otection, install additional CO Alarms in each separate bedr oom, and on every level of your home.
6 WHERE NOT T O INSTALL CO ALARMS DO NOT locate this CO Alarm: • In garages, kitchens, furnace r ooms, or in any extr emely dusty , dirty or greasy ar eas. • Closer than 20 feet fr om a furnace or other fuel burning heat sour ce, or fuel burning appliances like a water heater .
7 HOW TO INSTALL Y OUR CO ALARM W ARNING! This CO Alarm can not operate without continuous electricity . It does not operate during a power failur e. Do not use in an extension cor d, or outlet controlled by a dimmer or switch — unit must have a constant power supply .
8 CHAPTER 3: If Y our CO Alarm Alarms W ARNING! Actuation of your CO alarm indicates the presence of carbon monoxide (CO) which can kill you. In other wor ds, when your CO Alarm alarms, you must not ignor e it! If the Alarm Signal Sounds: 1. Operate the T est/Silence button.
9 Using the Silence Feature W ARNING! NEVER unplug your CO alarm to silence the horn. Use the silence featur e. Unplugging the CO alarm r emoves your protection! See previous page for details on r esponding to an alarm.
10 CHAPTER 4: T esting and Maintenance W EEKLY T ESTING Push and hold the T est/Silence button on the cover until a loud alarm sounds— 4 beeps, a pause, then 4 beeps. The alarm sequence should last for 5-6 seconds. If the Alarm ever fails to test pr operly , replace it immediately .
11 CHAPTER 5: What Y ou Need T o Know About CO What is CO? CO is an invisible, odorless, tasteless gas produced when fossil fuels do not bur n completely , or are exposed to heat (usually fi re). Electrical appliances typically do not produce CO. These fuels include: W ood, coal, char coal, oil, natural gas, gasoline, ker osene, and propane.
12 Potential Sources Of CO In The Home Fuel-burning appliances like: portable heater , gas or wood burning fireplace, gas kitchen range or cooktop, gas clothes dryer . Damaged or insuf fi cient venting: corroded or disconnected water heater vent pipe, leaking chimney pipe or flue, or cracked heat exchanger , blocked or clogged chimney opening.
13 How Can I Protect My Family? A CO Alarm is an excellent means of pr otection. It monitors the air and sounds a loud alarm before Carbon Monoxide levels become threatening for average, healthy adults. A CO Alarm is not a substitute for pr oper maintenance of home appliances.
14 CHAPTER 6: Underwriters Laboratories Inc. UL2034 What Levels of CO Cause an Alarm? Underwriters Laboratories Inc. UL2034 defi nes 3 specific alarm points by which all r esidential CO Alarms must alarm. They ar e measured in parts per million (ppm) of CO over time (in minutes).
15 CHAPTER 7: Troubleshooting Guide Problem... This means... You should... Green light is OFF. Unit will not alarm when you press the Test/Silence button. Unit may not be plugged all the way in, or is not receiving power. Gently push unit all the way into outlet.
16 CHAPTER 8: General Limitations Of CO Alarms This CO Alarm is intended for residential use. It is not intended for use in industrial applications where Occupational Safety and Health Administration (OSHA) requirements for carbon monoxide detectors must be met.
Limited W arranty Coverage: BRK Brands, Inc. warrants its enclosed carbon monoxide alarm to be free fr om defects in materials and workmanship under normal use for a period of five years from the date of purchase. During the first year after the date of purchase, BRK Brands, Inc.
Een belangrijk punt na aankoop van elk apparaat BRK electronic CO2120PN (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen BRK electronic CO2120PN heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens BRK electronic CO2120PN vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding BRK electronic CO2120PN leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over BRK electronic CO2120PN krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van BRK electronic CO2120PN bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de BRK electronic CO2120PN kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met BRK electronic CO2120PN . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.