5100-I W OOD INSER T 1445 Nor th Highwa y Colville, W A 99114 SA VE THESE INSTR UCTIONS www .quadrare .com P ar t 250-1960 Rev B J anuar y 30, 2004 O - T L Tested and Listed by Beaverton Oregon USA OMNI-Test Laboratories, Inc. C R PRIOR T O FIRST FIRE : Remove all labels from glass .
5100-I W OOD INSERT P age 2 Jan uar y 30, 2004 R 250-1960 Re v B Hearth & Home T echnologies welcomes y ou to our tradition of e xcellence! In choosing a Quadra-Fire appliance, y ou hav e our assurance of commitment to quality , durability , and perf or mance.
P age 3 Jan uar y 30, 2004 5100-I W OOD INSERT R 250-1960 Re v B SAFETY & O VER VIEW OF APPLIANCE Dimensions ----------------------------------------------------- 4 Minimum Clearances to Comb usti.
5100-I W OOD INSERT P age 4 Jan uar y 30, 2004 R 250-1960 Re v B DIMENSIONS T OP VIEW SIDE VIEW FR ONT VIEW STD 47” 30-1/2” Large 51-1/4” 34-1/4” P anel Size A B A B 39-1/8" (994mm) 26-3/.
P age 5 Jan uar y 30, 2004 5100-I W OOD INSERT R 250-1960 Re v B SERIAL NUMBER LABEL LOCA TION: ON RIGHT SIDE OF INSER T AS Y OU F A CE THE APPLIANCE In Canada a full length 6” (152mm) S635 ue liner required as per ULC S628. NO TE: When installling into a masonr y replace, the re- place must be built to UBC Chapter 37 standards.
5100-I W OOD INSERT P age 6 Jan uar y 30, 2004 R 250-1960 Re v B A V OID FIRE: T o ensure that insulation or any other combustible material does not contact the chimney , a chimney inside the house must hav e at least 2 inches (51mm) of air space clearance around t he chimney .
P age 7 Jan uar y 30, 2004 5100-I W OOD INSERT R 250-1960 Re v B IF INST ALLING THIS MODEL TO A MASONR Y CHIMNEY , AL W A YS BE SURE THE CHIMNEY IS IN GOOD CONDITION AND THA T IT MEETS THE MINIMUM ST ANDARDS OF THE NA TIONAL FIRE PR O TECTION ASSOCIA TION (NFP A) ST AND ARD 211.
5100-I W OOD INSERT P age 8 Jan uar y 30, 2004 R 250-1960 Re v B Floor Ceiling Caulk Floor (second Story) Non-Combustible Firestopping Material Minimum 1 inch (25mm) clearance from exterior chimney to.
P age 9 Jan uar y 30, 2004 5100-I W OOD INSERT R 250-1960 Re v B 1. An outside air inlet m ust be provided for combustion and must remain clear of leav es, debris, ice and/or snow . It must be unrestricted while unit is in use to pre vent room air star v ation which can cause smok e spillage and an inability to maintain a re.
5100-I W OOD INSERT P age 10 Jan uar y 30, 2004 R 250-1960 Re v B MASONR Y FIREPLA CE USING DIRECT -CONNECT METHOD Refer to: Clearances to Comb ustibles on page 5, Canadian Installation requirements on page 12, Hearth Requirements on page 5 and Zero Clearance Adjustable Support Kit on page 16.
P age 11 Jan uar y 30, 2004 5100-I W OOD INSERT R 250-1960 Re v B F A CT OR Y BUIL T ZERO CLEARANCE FIREPLA CE (USA INST ALLA T ONS ONL Y) The Quadra-Fire 5100-I Inser t is listed to UL Standards f or.
5100-I W OOD INSERT P age 12 Jan uar y 30, 2004 R 250-1960 Re v B INST ALLA TION IN CANAD A MASONR Y and HEA T -CIRCULA TING (INST ALLA TIONS INT O F A CT ORY-B UIL T FIREPLACES ARE PR OHIBITED IN CAN.
P age 13 Jan uar y 30, 2004 5100-I W OOD INSERT R 250-1960 Re v B NO TE: The 5100-I requires replacement of combustion air . If y our home is fairly air-tight, it is receommend that you install outside air . If you are installing into a Mobile Home, outside air is required.
5100-I W OOD INSERT P age 14 Jan uar y 30, 2004 R 250-1960 Re v B BLO WER REPLA CEMENT INSTRUCTIONS P ar t 832-1991 for Serial Numbers 131586 and below P ar t 832-3190 for Serial Numbers 131587 and abov e Figure 14A NO TE: When the speed control is turned clockwise , it will clic k on to high speed.
P age 15 Jan uar y 30, 2004 5100-I W OOD INSERT R 250-1960 Re v B ST AND ARD Size: 30-1/2” h x 47”w 831-1452, Gold T r im SP-51S-NL, Nick el T r im Figure 15A Figure 13B Do not tighten sides until.
5100-I W OOD INSERT P age 16 Jan uar y 30, 2004 R 250-1960 Re v B ZER O CLEARANCE ADJUST ABLE TRIM SUPPOR T , 2” to 10” P ar t No. ADJSPT -12, size 12” x 50” Included in Kit: ( 1) T r im T op .
P age 17 Jan uar y 30, 2004 5100-I W OOD INSERT R 250-1960 Re v B WOOD SELECTION AND ST ORA GE Burn only dry seasoned wood. Dr y , well-seasoned wood will not only minimize the chance of creosote f or mation but will give you the most efcient heat output.
5100-I W OOD INSERT P age 18 Jan uar y 30, 2004 R 250-1960 Re v B BURN RA TES ST ARTING FIRE : Open both controls (push in) completely . After a wood load has been burning on high f or 5 to 15 minutes or longer f or very large pieces, close the Star t-Up Air Control (right side) by pulling it out.
P age 19 Jan uar y 30, 2004 5100-I W OOD INSERT R 250-1960 Re v B AIR QU ALITY AND Y OUR QU ADRA-FIRE INSERT In recent y ears there has been an increasing concer n about the quality of our air . Much of the b lame f or poor air quality has been placed on the burning of wood for home heating.
5100-I W OOD INSERT P age 20 Jan uar y 30, 2004 R 250-1960 Re v B MAINTENANCE CARE AND CLEANING OF PLA TED SURF A CES IMPORT ANT : Y ou must clean all the ngerpr ints and oils from the plated surfaces bef ore ring the inser t f or the rst time.
P age 21 Jan uar y 30, 2004 5100-I W OOD INSERT R 250-1960 Re v B BRICK REPLA CEMENT INSTR UCTIONS FIREBO X BRICK SET , P AR T 832-1970 The rebo x of your Quadra-Fire 5100-I Inser t is lined with high quality rebr ic k which has e xceptional insulat- ing proper ties.
5100-I W OOD INSERT P age 22 Jan uar y 30, 2004 R 250-1960 Re v B SER VICE P AR TS 832-3100 Grille Assembly , Gold 832-3100NL Grille Assembly , Nick el 831-1520 Mantel Deector , 5” 831-1530 Mante.
P age 23 Jan uar y 30, 2004 5100-I W OOD INSERT R 250-1960 Re v B Lifetime Warranty LIMITED LIFETIME W ARRANTY The Hearth & Home T echnologies limited Lifetime Warranty guarantees that the following components will work as designed for the lifetime of the stove or Hearth & Home T echnologies will repair or replace them.
P age 24 Jan uar y 30, 2004 250-1960 Re v B R A TTENTION INST ALLER: Please return this man ual to the homeo wner when installation is complete ..
Een belangrijk punt na aankoop van elk apparaat Hearth and Home Technologies 5100-I (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Hearth and Home Technologies 5100-I heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Hearth and Home Technologies 5100-I vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Hearth and Home Technologies 5100-I leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Hearth and Home Technologies 5100-I krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Hearth and Home Technologies 5100-I bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Hearth and Home Technologies 5100-I kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Hearth and Home Technologies 5100-I . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.